Heavy Metals Testing for Supplements, Food & Cosmetics
Ensure safety, compliance, and consumer trust with expert heavy metals analysis.
Heavy metal testing is the process of quantifying arsenic, cadmium, lead, and mercury levels in consumer products using ICP-MS (Inductively Coupled Plasma Mass Spectrometry) instrumentation to ensure compliance with USP <2232>, California Prop 65, and FDA safety guidelines.
Our state-of-the-art laboratory specializes in accurate, regulatory-compliant heavy metals testing for dietary supplements, food products, and cosmetic formulations. Our advanced ICP-MS methodologies, experienced chemists, and FDA-audited protocols ensure your products meet the highest safety and quality standards.
Why Heavy Metals Testing Is Critical
Heavy metals like arsenic, lead, cadmium, and mercury are toxic even at low concentrations. They can contaminate ingredients through soil, water, processing equipment, and packaging. Regulatory bodies require strict compliance with heavy metal limits to prevent neurotoxicity, kidney damage, developmental delays, and carcinogenicity.
Metals We Test For
We test for all commonly regulated metals: Lead (Pb), Cadmium (Cd), Arsenic (As — total and inorganic), Mercury (Hg — total and methylmercury), Nickel (Ni), Chromium (Cr), Tin (Sn), Cobalt (Co), Antimony (Sb), Thallium (Tl), Copper (Cu), and Zinc (Zn). Custom panels and additional trace metal screening available on request.
ICP-MS Technology
Our laboratory uses ICP-MS (Inductively Coupled Plasma Mass Spectrometry) — the gold standard for multi-element trace detection at parts-per-billion (ppb) sensitivity. This enables reliable, reproducible results at concentrations far below regulatory limits.
California Prop 65 Compliance
We provide heavy metal testing aligned with California Prop 65 maximum allowable dose levels (MADLs) and No Significant Risk Levels (NSRLs). Our reports include all documentation required for Prop 65 compliance and Amazon listing requirements.
الاختبارات والأساليب المدرجة
- ✓ Lead (Pb)
- ✓ Cadmium (Cd)
- ✓ Arsenic (As) — total & inorganic
- ✓ Mercury (Hg)
- ✓ Multi-element ICP-MS panel
- ✓ Prop 65 compliance panel
المعايير التنظيمية والامتثال
- USP <2232> Elemental Contaminants
- ICH Q3D
- California Prop 65
- FDA 21 CFR guidelines
- EU Regulation 1881/2006
القطاعات التي نخدمها
- Dietary supplements
- Herbal & botanical products
- Cosmetics & personal care
- Food & functional foods
- Amazon FBA sellers
احصل على عرض سعر
يعتمد السعر على منتجك. أخبرنا بما تحتاجه وسنرسل لك عرض سعر مفصلاً خلال 24 ساعة.
احصل على عرض سعر →الأسئلة الشائعة
What heavy metals does Qalitex test for?
Qalitex tests for lead (Pb), cadmium (Cd), arsenic (As — total and inorganic), mercury (Hg), nickel, chromium, tin, cobalt, antimony, thallium, copper, and zinc using ICP-MS instrumentation with parts-per-billion sensitivity.
What is ICP-MS and why is it the gold standard for heavy metal testing?
ICP-MS (Inductively Coupled Plasma Mass Spectrometry) is the gold standard for multi-element trace metal detection because it can reliably detect metals at parts-per-billion concentrations — far below regulatory limits set by USP, Prop 65, and FDA guidelines.
Does Qalitex offer California Prop 65 heavy metal testing?
Yes, Qalitex provides heavy metal testing aligned with California Prop 65 maximum allowable dose levels (MADLs) and No Significant Risk Levels (NSRLs). Testing reports include all documentation required for Prop 65 compliance and Amazon listing requirements.
صفحات الاختبارات المتخصصة
Heavy Metal Testing Near Irvine & San Diego, CA — ISO 17025 Accredited Lab
heavy metal testing near me
Heavy Metal Testing in California — ISO 17025 Accredited Lab
heavy metal testing California
Heavy Metal Testing Near Los Angeles — ISO 17025 Accredited Lab
heavy metal testing Los Angeles
Heavy Metal Testing for Cosmetics — Expert Lab Services
heavy metal testing for cosmetics
Heavy Metal Testing for Nutraceuticals — Expert Lab Services
heavy metal testing for nutraceuticals
Heavy Metal Testing for Dietary supplements — Expert Lab Services
heavy metal testing for dietary supplements
لماذا تختار العلامات التجارية Qalitex لـ heavy metal testing by icp-ms
تسليم خلال 48 ساعة
CoA موقع في 48–72 ساعة
وصول مباشر للعلماء
تحدث مع الكيميائي المسؤول عن اختباراتك
لا حد أدنى للطلب
1 SKU أو 100 — نفس الجودة
مقالات ذات صلة
Acrylamide in Food: What California's Prop 65 NSRL Actually Means for Food Brands
California's Prop 65 NSRL for acrylamide is 0.2 mcg/day — a threshold snack foods routinely exceed. Learn how food safety laboratories test and document it.
Chemical TestingICP-MS vs. ICP-OES: Which Heavy Metal Testing Method Does Your Product Actually Need?
ICP-MS and ICP-OES both test heavy metals, but choosing wrong can cost you compliance. Learn which method fits Prop 65, USP <232>, and your product type.
Dietary SupplementsKratom in 2026: How the State-by-State Regulatory Patchwork Defines Your Testing Requirements
With 6 states banning kratom and 8+ KCPA states, compliance in 2026 means testing to the strictest standard in your distribution footprint.
Chemical TestingICP-MS vs. ICP-OES: How to Choose the Right Heavy Metal Testing Method for Supplements and Cosmetics
ICP-MS and ICP-OES both measure heavy metals — but choosing the wrong method can produce compliance data that doesn't hold up. Here's how to decide.
هل أنت مستعد لاختبار منتجك؟
أخبرنا بما تحتاج إلى اختباره. سنرد خلال 24 ساعة بالأسعار وأوقات التسليم.
احصل على عرض سعر →إخلاء المسؤولية: نتائج الاختبارات التي تقدمها Qalitex Laboratories هي بيانات تحليلية لأغراض مراقبة الجودة. لا تشكل مشورة قانونية أو تنظيمية أو امتثالية. يتحمل العملاء المسؤولية الكاملة عن ضمان امتثال منتجاتهم لجميع اللوائح الفيدرالية والولائية والمحلية المعمول بها.